Troubleshooting Guide

Troubleshooting Unit With No Power
Situation Test Diagram
Green power light is off —> check the GFCl/RCD Push Reset button(s) in and verify that lights comes on or the pump starts
If green light remains off —> test the outlet to make sure it is delivering power

Local maintenance and repair regulations will dictate who will perform this testing from this point on:

Confirm outlet delivers power if not plug unit into a working outlet

If after resetting the CGFI/RCD trips once again… Move on to Troubleshooting: Tripping Breakers Section
If CGFI and Power are both functional but there is still no power to the machine The circuit board, power cord, or power supply may need replacement. Contact “CRC Technical Service” for Instructions or contact a qualified technician
Troubleshooting Unit that is Tripping Circuit Breakers
Situation Testing

Local maintenance and repair regulations will dictate who will perform this testing from this point on:

Check if the repeated tripping is occurring at the breaker

Possible line overload; plug Unit into another outlet that is not on the same breaker
If still experiencing repeated tripping at the GFCI/RCD Outlet Most common cause for tripping the GFCI/RCD outlet is either a pump or heater issue
Follow these simple instructions to determine if you need a new pump

Local maintenance and repair regulations will dictate who will perform this testing from this point on:

Test: disconnect pump wires and check that GFCI/RCD remains reset; if it does then Pump requires replacement.

Watch Pump Replacement Video: Watch Video

If test shows pump is working then determine if the heater needs replacement

Test: disconnect heater wires and check that GFCI/RCD remains reset; if it does then Heater requires replacement.

Watch Heater Replacement Video: Watch Video

Troubleshooting Unit that is Not Pumping
Situation Test Diagram
If green power light is flashing Call your local CRC Technical Service
If green light is off… Make sure the unit is plugged into a working power outlet and GFCI/RCD is not tripped
If power is on then check to see if the fuse is melted

Local maintenance and repair regulations will dictate who will perform this testing from this point on:

Test: check pump fuse in control box, labeled FI, and replace if needed

If fuse is functional or continues to fail

Perform pump replacement

Watch Pump Replacement Video: Watch Video

Troubleshooting Unit that is Over Heating/ Not Heating
Situation Test Diagram
Is Unit Overheating?
Temperature >115°F/46°C
Contact your local “CRC Technical Service”
If the green power light is blinking and unit is not pumping

Local maintenance and repair regulations will dictate who will perform this testing & part replacement from this point on:

Perform probe replacement.

Watch Probe Replacement Video: Watch Video

If the red Add Fluid Light is On Add (1) 5-Gallon (20 lt) container of OzzyJuice® to the unit, confirm red light goes out, allow up to 3 h for liquid to reach operating temperature
If after 3h the liquid is still cold Test: check heater fuse in control box, labeled F2, and replace if melted
If the heater fuse is good

Perform probe replacement

Watch Probe Replacement Video: Watch Video

If heater fuse continues to fail

Perform heater replacement

Watch Heater Replacement Video: Watch Video